可靠性试验项目 Reliability Testing Items
序号 No. | 项目 Items | 要求 Requirements | 试验方法及备注 Test Methods and Remarks |
1 | 工作温度范围 Operating Temperature Range | FHW-UC/HC series:-40℃~+125℃ FHW-UF/IF/QF/HF series:-40℃~+85℃ | |
2 | 可焊性 Solder ability
| 外观不发生变化;超过90%的焊锡覆盖在端电极表面 There shall be no case deformation or change in appearance. The metalized area must have more than 90% solder coverage. | 在 245±5℃ 熔 融 的 焊 锡 (96.5Sn/3.0Ag/0.5Cu)中浸置 5±1 秒钟。 Dip pads in flux and dip in solder pot(96.5Sn/3.0Ag/0.5Cu)at 245±5℃ for 5±1 seconds. |
3 | 耐焊接热 Soldering Heat Resistance
| 外观不发生变化;感量变化不超过±5%; Q值变化不超过±10%。 There shall be no case deformation or change in appearance. Inductance shall not change more than ±5%; Q shall not change more than±10%. | 在 260±5℃ 熔 融 的 焊 锡 (96.5Sn/3.0Ag/0.5Cu)中浸置 10±1 秒钟。 Dip pads in flux and dip in solder pot(96.5Sn/3.0Ag/0.5Cu)at 260±5℃ for 10±1 seconds. |
4 | 介质耐压 Dielectric Withstand Voltage
| 外观不发生变化;无击穿现象 here shall be no case deformation or change in appearance.No evidence of voltage breakdown. | 在电感器端子和包封层间施加 500V 交流电压,持续一分钟。 Input 500v AC between the electrodes and the resin of inductor and keep on one minute. |
5 | 绝缘电阻 Insulation Resistance | 铁氧体芯: ≥500MΩ 陶瓷芯:≥1000 MΩ Ferrite: ≥500MΩ Ceramic: ≥1000 MΩ | 在电感器端子和包封层间施加 100V 直流电压,持续一分钟。 Input 100v DC between the electrodes and the resin of inductor and keep on one minute. |
6 | 端电极附着力 (推力测试) Component Adhesion (Push of test) | 绕线型片式电感器: Wire Wound Chip inductor: 0402UC series:≥0.45Kg 0603UF series:≥0.9Kg 0603UC series、0805UF series:≥1.3 Kg Other series: ≥2Kg |
|
序号 No. | 项目 Items | 要求 Requirements | 试验方法及备注 Test Methods and Remarks |
7 | 过载 Over Loading | 外观不发生变化;电感器不开路. There shall be no case deformation or change in appearance. Inductors shall not have a open winding. | 将规定额定电流2倍的直流电流加于电感器,其电流误差为±2%,,保持 5 分钟。 Direct current of rating current between inductor terminals , Direct current error ±2%, and keep on five minutes. |
8 | 振 动 Vibration | 无开路或短路; 感量变化不超过±5%; Q值变化不超过±10%。 Inductors shall not have a shorted or open winding. Inductance shall not change more than ±5%. Q shall not change more than±10%. | 振幅 1.5mm,频率 10~55Hz,每个方向保持2小时。 Inductors shall be subjected to vibration of 1.5mm amplitude frequency 10~55Hz (10Hz to 55Hz to 10Hz in a period of 1 minute) for 2 hours in each of three(X、Y、Z) axes. |
9 | 温度变化 Temperature Change | 外观不发生变化;感量变化不超过±5%; Q值变化不超过±10% There shall be no case deformation or change in appearance. Inductance shall not change more than ±5%. Q shall not change more than±10%. | FHW-UC/HC 系列: +125℃ 60 分钟 ← → -40℃ 60分,钟循环5次; FHW-UF/IF/QF/HF 系列:+85℃ 60分钟 ←→ -40℃ 60分,钟循环5次;室温下放置一小时后测试。 FHW-UC/HC series :+125℃ 60minutes ←→ -40℃ 60minutes 5 Cycles; FHW-UF/IF/QF/HF series : +85℃ 60minutes ←→ -40℃ 60minutes 5 Cycles; Inductors are to be tested after 1 hour at room temperature. |
10 |
高温 High temperature | 外观不发生变化;感量变化不超过±5%; Q值变化不超过±10% There shall be no case deformation or change in appearance. Inductance shall not change more than ±5%. Q shall not change more than ±10%. | FHW-UC/HC 系列产品放置于温度+125 ±5℃的环境中存放96±2小时; FHW-UF/IF/QF/HF 系列产品放置于温度 +85±5℃的环境中存放96±2小时;在室温下放置1小时后进行测试。 FHW-UC/HC series shall be subjected to +125±5℃ for 96±2 hours; FHW-UF/IF/QF/HF series shall be subjected to +85±5℃ for 96±2 hours; Inductors are to be tested after one hour at room temperature. |
序号 No. | 项目 Items | 要求 Requirements | 试验方法及备注 Test Methods and Remarks |
11 | 低温 Low temperature | 外观不发生变化;感量变化不超过±5%; Q值变化不超过±10% There shall be no case deformation or change in appearance. Inductance shall not change more than ±5%. Q shall not change more than±10% | 将电感器放置于温度-40±2℃的环境中存放96±2小时,然后在室温下放置 1小时后进行测试。 Inductors shall be subjected to -40±2℃for 96±2 hours. Inductors are to be tested after one hour at room temperature. |
12 | 恒定湿热 Static Humidity | 外观不发生变化;感量变化不超过±5%; Q值变化不超过±10% There shall be no case deformation or change in appearance. Inductance shall not change more than ±5%. Q shall not change more than±10%. | 将电感器放置在于湿度93±3%,温度50 ±2℃的环境中存放96±2小时,经过1 小时的风干后进行测试。 Inductors shall be subjected to 93±3% R.H. at 50±2℃ for 96±2 hours .Inductors are to be tested after having air dried for one hou. |
13
|
耐久性 durability (Life)
| 电感器不应短路或断路。 Inductors shall not have a shorted or open winding.
| FHW-UC/HC 系列产品加额定电流在 125 ±2℃温度条件下存放1000小时; FHW-UF/IF/QF/HF 系列产品加额定电流在85±2℃温度条件下存放1000小时;然后在室温下放置4小时后进行测试。 FHW-UC/HC series shall be store at 125±2℃ for 1000 hours with rated current applied; FHW-UF/IF/QF/HF series shall be store at 85±2℃ for 1000 hours with rated current applied; Inductors shall be tested after four hours at room temperature.
|